MarForm | ์†Œํ˜• ํฌ๊ธฐ์˜ ์ธก์ • ๊ธฐ๊ณ„

MarForm MMQ 200

์ œํ’ˆ๋ฒˆํ˜ธ 5440750

Compact form measuring device with innovative T20W probe system for production and precision measuring room

MMQ 200์€ ์ œ์กฐ ์ž‘์—…์žฅ๊ณผ ๊ฒ€์‚ฌ์‹ค์„ ์œ„ํ•œ ์ปดํŒฉํŠธํ•œ ํฌ๊ธฐ์˜ ์ธก์ • ๊ธฐ๊ณ„์ž…๋‹ˆ๋‹ค. ๋‘ ๊ฐ€์ง€ ๋ฒ„์ „ ์‚ฌ์šฉ ๊ฐ€๋Šฅ: T20W ๋Š” ๋ฒ”์šฉ ์ธก์ • ํ”„๋กœ๋ธŒ๋ฅผ ํฌํ•จํ•œ ์ธก์ • ์Šคํ…Œ์ด์…˜์ด๊ณ , T7W๋Š” ๋ชจํ„ฐ ๊ตฌ๋™์‹ ์ธก์ • ํ”„๋กœ๋ธŒ๋ฅผ ํฌํ•จํ•œ ์ธก์ • ์Šคํ…Œ์ด์…˜์œผ๋กœ ๋…์ž์ ์ธ ๋ชจํ„ฐ ๊ตฌ๋™์‹์œผ๋กœ ์ž๋™ํ™”์˜ ๋„์•ฝ์„ ์ด๋ฃจ์—ˆ์Šต๋‹ˆ๋‹ค.

MarForm MMQ 200
MarForm MMQ 200
MMQ 200์€ ์ œ์กฐ ์ž‘์—…์žฅ๊ณผ ๊ฒ€์‚ฌ์‹ค์„ ์œ„ํ•œ ์ปดํŒฉํŠธํ•œ ํฌ๊ธฐ์˜ ์ธก์ • ๊ธฐ๊ณ„์ž…๋‹ˆ๋‹ค.

  • DIN/ISO 1101์— ๋”ฐ๋ฅธ ํ˜•์ƒ ๋ฐ ์œ„์น˜ ํŽธ์ฐจ ๊ฒ€์ฆ
  • ์™„์ „ ์ž๋™์‹ ์ธก์ • ์ˆœ์„œ
  • ์ •๋ฐ€ ์ง„์›๋„ ์ธก์ • ์ถ• (C)
  • ๋ชจํ„ฐ ๊ตฌ๋™์‹ ์ˆ˜์ง ์ธก์ • ์ถ• (Z)
  • ๋ชจํ„ฐ ๊ตฌ๋™์‹ ์ˆ˜ํ‰ ์œ„์น˜ ์ด๋™ ์ถ• (X)
  • ์ˆ˜๋™ ์„ผํ„ฐ๋ง ๋ฐ ํ‹ธํŒ… ํ…Œ์ด๋ธ”
  • T20W ์ˆ˜๋™ ๊ธธ์ด ์ธก์ • ํ”„๋กœ๋ธŒ ๋˜๋Š”
  • T7W ๋ชจํ„ฐ ๊ตฌ๋™์‹ ํ”„๋กœ๋ธŒ
  • ์ธ์ฒด๊ณตํ•™์  ์ œ์–ดํŒ - ์„ ํƒํ•œ ์ธก์ • ํ”„๋กœ๊ทธ๋žจ(P1, P2, P3)์„ ์‹œ์ž‘ํ•˜๋Š” ๋ฐ ์‚ฌ์šฉ ๊ฐ€๋Šฅ
T7W ๋ชจํ„ฐ ๊ตฌ๋™์‹ ํ”„๋กœ๋ธŒ

๋ชจํ„ฐ ๊ตฌ๋™์‹ ํ”„๋กœ๋ธŒ T7W์™€ ํ•จ๊ป˜ ์‚ฌ์šฉํ•  ๊ฒฝ์šฐ, MMQ 200์€ ๊ฑฐ์น ๊ธฐ ๋ฐ ๋ฆฌ๋“œ ์ธก์ •์—๋„ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
๋”ฐ๋ผ์„œ MMQ 200์€ ๋™๊ธ‰ ์ œํ’ˆ ์ค‘์—์„œ ๊ฐ€์žฅ ๋ฒ”์šฉ์œผ๋กœ ํ™œ์šฉํ•  ์ˆ˜ ์žˆ๋Š” ์ธก์ • ์‹œ์Šคํ…œ์œผ๋กœ, ๋น„๊ตํ•  ์ˆ˜ ์—†๋Š” ํƒ์›”ํ•œ ๊ฐ€๊ฒฉ๋Œ€ ์„ฑ๋Šฅ๋น„๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
The inductive touch probe T20W can be used very flexibly. Thanks to the probe arm, which can be moved through an angle of 190ยฐ, and the various clamping options for the probe, measurements can also be taken in places that are difficult to access. To adapt the probe to the respective measuring tasks or workpieces, you can combine easily interchangeable probe arms with different measuring inserts.
MarForm MMQ 200 | ํ’ˆ๋ชฉ ๋ฒˆํ˜ธ 5440750
Pos.-/Meas. path X-axis 150 mm
Pos.-/Meas. path Z-axis 250 mm
Positioning speed C-axis 0.2 - 20 1/min
์œ„์น˜ ์ด๋™ ์†๋„(mm/s), X์ถ• 0.5 - 30 mm/s
Positioning speed Z-axis 0.5 - 100 mm/s
Workpiece diameter max. 210 mm
Straightness deviation Z-axis 0.15 ยตm/100 mm
์ž‘๋™ ์˜จ๋„ 20 ยฐC
์„ผํ„ฐ๋ง ๋ฐ ํ‹ธํŒ… ํ…Œ์ด๋ธ” ์ˆ˜๋™
ํ…Œ์ด๋ธ” ์ง€๋ฆ„ (mm) 160 mm
Table load max. 20 kg
ํ”„๋กœ๋ธŒ ์‹œ์Šคํ…œ ํƒ€์ž… ์ ‘์ด‰ 1D
์Šต๋„ (ํ…์ŠคํŠธ) max. 70 % relative humidity; non-condensing
๊ณต๊ธ‰ ํ’ˆ๋ชฉ(ํ…์ŠคํŠธ) Probe system T20W (incl. probe arm โŒ€ย 3ย xย 60ย mm)

์ œํ’ˆ์˜ ๋‹ค์–‘ํ•œ ์‘์šฉ ๋ถ„์•ผ

  • Mechanical engineering:
    Bearings, ball screws, shafts, sockets, rotational bushings
  • Measurement close to production:
    PLC and end-of-line testing
  • Automotive:
    Steering, brake system, gearbox, motor
  • Medicine:
    Hip and knee endoprostheses,ย medical screws,ย teeth implants
์ œํ’ˆ๋ช… ์ œํ’ˆ๋ฒˆํ˜ธ
Rel_MarForm MarWin
MarWin MarForm
Rel_MarForm
์ง๊ด€์ ์ธ ํ•ธ๋“ค๋ง
์ง๊ด€์ ์ธ MarWin EasyForm ์†Œํ”„ํŠธ์›จ์–ด๋Š” ์ž‘์—…์„ ๋งค์šฐ ์ˆ˜์›”ํ•˜๊ฒŒ ํ•ด์ค๋‹ˆ๋‹ค. 3๋ฒˆ์˜ ํด๋ฆญ๋งŒ์œผ๋กœ ์ธก์ •์„ ์‹คํ–‰ํ•  ์ˆ˜ ์žˆ๊ณ , ์œ ์šฉํ•œ ์ •๋ณด๋ฅผ ํฌํ•จํ•œ ์ธก์ • ๊ธฐ๋ก์„ ํ™•๋ณดํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
๊ฒฐํ•ฉ ๋œ ์ธก์ • ๋ฐฉ๋ฒ•
์ž๋™ ํ”„๋กœ๋ธŒ T7W์™€ ํ•จ๊ป˜ MMQ200์€ ํ˜•์ƒ, ๊ฑฐ์น ๊ธฐ ๋ฐ ๋ฆฌ๋“œ ํŒŒ๋ผ๋ฏธํ„ฐ์˜ ํ†ตํ•ฉ ์ธก์ •์„ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
๋™๊ธ‰ ์ œํ’ˆ๊ตฐ์—์„œ ์œ ๋‹ˆํฌํ•œ ์†”๋ฃจ์…˜์œผ๋กœ, ๋งค์šฐ ๊ฒฝ์ œ์ ์ธ ๋ฐฉ์‹์œผ๋กœ ๊ธฐ๋Šฅ์„ ๊ตฌํ˜„ํ•˜์˜€์Šต๋‹ˆ๋‹ค.
์ž‘์—…์ž ์‹œ๊ฐ„ ํ™•๋ณด
์ž๋™์ถ• ๋ฐ T7W ํ”„๋กœ๋ธŒ ๋•๋ถ„์— ์ž๋™ ์ธก์ • ์‹คํ–‰์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค. ํ”„๋กœ๋ธŒ๋Š” ์†Œํ”„ํŠธ์›จ์–ด๋ฅผ ์‚ฌ์šฉํ•ด ๋‚ด์ธก/์™ธ์ธก ์ธก์ •๊ณผ ์ˆ˜ํ‰/์ˆ˜์ง ์ธก์ • ๊ฐ„์„ ์ „ํ™˜ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
์œ„๋กœ